Turbomachinery Control Solution - Integrated Turbine & Compressor Control

Turbomachinery Control Solution - Integrated Turbine & Compressor Control

  • Add to My Bookmarks
  • SHARE 

​Honeywell offers the Turbomachinery Control Solution, an integrated turbine and compressor control solution, to utility and industrial users to replace their obsolete proprietary black box turbine and compressor controls. Equipment use is optimized through integration with Experion® PKS, resulting in operational costs savings annually.

Efficient turbine and compressor controls and operations

Turbomachinery Control Solution provides:

• Tighter control over the speed of steam, hydro and gas turbines while ensuring over-speed protection

• Surge protection for compressors, enabling users to operate closer to the surge curve safely

• Load balancing between compressors or generators to allow for more efficient use of resources

• Standard operating environment, alarm management capabilities and an intuitive operator interface.

 

Multiple versions of the Turbomachinery Control Solution are available for different applications:

• Utility Steam Turbine – Turbine control for reheat and non-reheat steam turbines. 

• Industrial Steam Turbine – Extraction and back-pressure steam turbine control

• Industrial Gas Turbine – Fuel control and turbine sequencing control

• Hydroelectric Turbine – Turbine control

• Compressors – Centrifugal and axial anti-surge, performance, and sequencing control.

Tight integration with Experion​

Turbomachinery Control Solution utilizes Experion PKS’ C300 controller and Series C input/output (I/O) modules designed specifically for turbomachinery control. The solution provides direct interfacing with field devices such as magnetic active and passive speed probes, and linear variable displacement transducers without the need for proprietary black box hardware or signal converters. It thus eliminates the need for traditional proprietary black box controllers.

Integration with Experion provides unified control and a common set of engineering and maintenance tools for ease of use and reduced need for training.

​Turbomachinery Control Solution saves costs and improves operational efficiency by:

• eliminating the need to integrate proprietary black box solutions into Experion PKS

• making specialized training for operations and maintenance personnel unnecessary

• doing away with the need to stock specialized spares.

Documentation
10 Documents FoundItems per page :
TitleUse SHIFT+ENTER to open the menu (new window).
DescriptionUse SHIFT+ENTER to open the menu (new window).
File SizeUse SHIFT+ENTER to open the menu (new window).
TypeUse SHIFT+ENTER to open the menu (new window).
Release DateUse SHIFT+ENTER to open the menu (new window).
Advanced Digital Steam Turbine Control on the Experion PlatformThe Honeywell Turbine Control System is based on the Experion® Process Knowledge System (PKS) platform. Experion integrates process control with advanced solutions and services in an open system environment that increases safety, reliability, efficiency and security.467.81 KBApplication Note18 Jan 2016
Experion Turbomachinery Extraction Turbine Control SolutionAppication Note - Experion Turbomachinery Extraction Turbine Control Solution222.59 KBApplication Note12 Sep 2014
Experion Turbomachinery Hydro TurbineApplication Note - Experion Turbomachinery Hydro Turbine629.68 KBApplication Note12 Sep 2014
Heavy Industrial Gas Turbine ControlsApplication Note on Heavy Industrial Gas Turbine Controls323.7 KBApplication Note12 Sep 2014
Steam Turbine Driven Compressor ControlsApplication Note on Steam Turbine Driven Compressor Controls325.39 KBApplication Note12 Sep 2014
Experion PKS Turbomachinery Test CertificateExperion PKS Turbomachinery Test Certificate by SKODA.642.52 KBProduct Information Note16 Jan 2013
United Energy Reduces Engineering and Maintenance with Experion Turbo Machinery ControlHoneywell’s fully integrated Experion® Turbo Machinery Control solution enabled United Energy to reduce engineering and maintenance efforts involved in maintaining reliable and stable heat and electric generation capacity.212.56 KBCase Study12 Dec 2012
Experion Turbomachinery Control Solution PINProduct Information Note - Turbomachinery Control Solution.172.56 KBProduct Information Note25 Oct 2012
Case Study for Dresser Rand Ethylene CompressorCase Study for Dresser Rand Ethylene Compressor.1.74 MBCase Study17 Oct 2012
Experion Automatic Turbine Startup SolutionExperion Automatic Turbine Startup Solution Turbomachinery Control.221.34 KBApplication Note17 Oct 2012
2 Documents FoundItems per page :
TitleUse SHIFT+ENTER to open the menu (new window).
DescriptionUse SHIFT+ENTER to open the menu (new window).
File SizeUse SHIFT+ENTER to open the menu (new window).
Release DateUse SHIFT+ENTER to open the menu (new window).
United Energy Reduces Engineering and Maintenance with Experion Turbo Machinery ControlHoneywell’s fully integrated Experion® Turbo Machinery Control solution enabled United Energy to reduce engineering and maintenance efforts involved in maintaining reliable and stable heat and electric generation capacity.212.56 KB12 Dec 2012
Case Study for Dresser Rand Ethylene CompressorCase Study for Dresser Rand Ethylene Compressor.1.74 MB17 Oct 2012

​Training, maintenance and support are critical aspects to consider when choosing a technology partner. Honeywell offers world-class training through our Automation College, as well as comprehensive maintenance and support services designed to leverage your physical and intellectual assets and help you sustain and increase their value and performance over time.

 
 
 
 
Want to learn more about Turbomachinery Control Solution?

Finding the information you need is important to us.

Did you find what you were looking for today?

  Yes      No

How likely are you to recommend HoneywellProcess.com to a colleague?

  • 0
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10

Not at all likely

Extremely likely

How can we serve you better?

Your email:

Your email address will help us get in touch with you to resolve your query/ concern.