APT2000 Contacting Conductivity Transmitter

APT2000 Contacting Conductivity Transmitter

  • Add to My Bookmarks
  • SHARE 

​Conductivity measurement devices determine conductivity, resistivity and salinity in a wide range of processes. Honeywell’s Analytical Process Analyzer (APT) 2000 series of Contacting Conductivity (CC) transmitters ensure reliable and accurate measurement and are ideal for chemical, petrochemical, pulp and paper, pharmaceutical, water and power industries. ​

​Honeywell’s APT2000CC transmitter includes advanced features that help diagnose and rectify errors occurring in electronic equipment. It also offers continuous diagnostics for monitoring calibration, cell health and analyzer self-test.

The APT2000 series works with a variety of Honeywell contacting conductivity cells for accuracy in high purity water measurement up to high conductivity or salinity and can meet the measurement needs of Class I, Division 2 (non-incendive) and general-purpose areas.

With quick response time, a simple operator interface and a large front display, the device enables quick recognition of process parameters and diagnostics from a distance.

Available in wall, pipe or panel mounting options, the APT2000 series can be easily installed with preassembled empty enclosure and plug-in terminals.  

​Honeywell’s APT2000CC transmitter is a two-wire 24 volt device that continuously monitors sensor and analyzer electronics and immediately displays diagnostics information. When an error occurs, the device indicates the appropriate error code or pictograph, blinks a red LED and adjusts the error current to 22 mA. 

The device’s large front display employs visual feedback (i.e. easily recognizable pictograph-type characters) to alert the operator during process changes and when problems occur. This enables easy troubleshooting, reduces the time required for set up and maintenance and minimizes calibration errors.  

​Inaccurate or unreliable conductivity measurements can result in heavy loss or process inefficiencies. Honeywell’s APT2000CC transmitter is easy to use and install. Designed for quick, accurate diagnosis and error rectification, the device is a reliable and cost-effective solution. 

Explore the rest of the Product Family

Documentation
8 Documents FoundItems per page :
TitleUse SHIFT+ENTER to open the menu (new window).
DescriptionUse SHIFT+ENTER to open the menu (new window).
SizeUse SHIFT+ENTER to open the menu (new window).
TypeUse SHIFT+ENTER to open the menu (new window).
Release DateUse SHIFT+ENTER to open the menu (new window).
Analyzers Seriers APT2000 Analytical Process Transmitter, 51-52-16-48-Issue 23Analyzers Seriers APT2000 Analytical Process Transmitter, 51-52-16-48-Issue 2371.77 KBModel Selection Guide1 Jan 2015
Smart Sensors and Analytical Instruments BrochureAnalytical brochure - measurements for pH, ORP, conductivity/resistivity, dissolved oxygen and hydrogen purity.1.55 MBBrochure22 Apr 2014
Field Products Brochure for Power IndustryHoneywell offers a complete range of innovative products to meet application requirements in the power and energy markets.4.28 MBBrochure5 Nov 2013
Analyzer Series APT2000 Analytical Process Transmitter, 51-52-16-48Analyzer Series APT2000 Analytical Process Transmitter, 51-52-16-4871.26 KBModel Selection Guide30 Oct 2013
UDA2182 Series and APT Series Specification, 70-82-03-14UDA2182 Series and APT Series Specification, 70-82-03-14. Industrial Electrolytic Conductivity Cells.165.53 KBTech Spec3 Oct 2012
Field and process instrumentation and controller solutions for the pulp and paper industry brochure Learn how Honeywell's transmitters, flow meters, controllers and analytical instrumentation solve problems for the pulp, paper and printing industry.3.45 MBBrochure10 Jun 2012
Improving Power Plant Efficiency and Extending Equipment Life Brochure on how analytical instruments can improve power plant efficiency.1.04 MBBrochure30 Sep 2011
Remote Analytical Measurements Use wireless networking to gather remote analytical measurements 454.88 KBSolution Note6 Feb 2008
Public Support Documentation
3 Documents FoundItems per page :
TitleUse SHIFT+ENTER to open the menu (new window).
DescriptionUse SHIFT+ENTER to open the menu (new window).
SizeUse SHIFT+ENTER to open the menu (new window).
TypeUse SHIFT+ENTER to open the menu (new window).
Release DateUse SHIFT+ENTER to open the menu (new window).
Analyzers and Transmitters: UDA2182, Direct Line 42x, APT2000/4000 China RoHS Disclosure. Hazardous Substance Disclosure Table. English/Chinese 443.11 KBSupport Document24 Jun 2016
APT2000 Contacting Conductivity Transmitter_70-82-57-07 Provides information about APT2000 Contacting Conductivity Transmitter53.02 KBSupport Document1 Mar 2000
APT2000 Series 2-Wire Contacting User Manual, 70-82-25-95APT2000 Series 2-Wire Contacting Conductivity Transmitters996.95 KBSupport Manual1 Jan 2000

Inaccurate or unreliable conductivity measurements can result in heavy loss or process inefficiencies. Honeywell’s APT2000CC transmitter is easy to use and install. Designed for quick, accurate diagnosis and error rectification, the device is a reliable and cost-effective solution.  ​

 
 
 
 
Want to learn more about APT2000 Contacting Conductivity Transmitter?

Finding the information you need is important to us.

Did you find what you were looking for today?

  Yes      No

How likely are you to recommend HoneywellProcess.com to a colleague?

  • 0
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10

Not at all likely

Extremely likely

How can we serve you better?

Your email:

Your email address will help us get in touch with you to resolve your query/ concern.