SmartLine Multivariable Transmitters

SmartLine Multivariable Transmitters

  • Add to My Bookmarks
  • SHARE 

Honeywell’s SmartLine Multivariable Transmitters (SMV800) extend its proven smart technology to the simultaneous measurement of three separate process variables according to standard industry methods for air, gases, steam and liquids. They also offer the ability to calculate compensated mass or volume flow rate as a fourth process variable. In addition, meter body-only components are also available to support third party and OEM metering solutions.

SmartLine Multivariable Transmitters can measure:

  • Differential pressure across a primary flow element such as an averaging pitot tube, venturi, flow nozzle, orifice plate, V-Cone®, wafer cone, wedge, etc. 

  • Static process pressure from a single sensor

  • Process temperature from thermocouple or Resistance Temperature Detector (RTD) inputs.


The transmitters offer the following features:

  • Accuracy of up to 0.04% for differential pressure

  • Accuracy of up to 0.0375% for static pressure

  • Accuracy of up to 0.2°C for temperature

  • Mass flow accuracy of up to 0.6%

  • Built-in static pressure & temperature compensation

  • Rangeability of up to 400:1

  • Compensated flow response time of up to 2x per second

  • Multiple local display capabilities 

  • Universal transmitter wiring

  • Modular design characteristics

  • Universal temperature input option

  • HART 7/DE protocol support

  • Built-in fail-safe feature for flow measurement. 

SmartLine Multivariable Transmitters have a unique single capsule sensor design, with a piezoresistive sensor as the measuring means. The sensor contains a differential pressure sensor and an absolute or a gauge pressure sensor, providing highly accurate and stable measurements.

The flexible software of the transmitters further allows flow calculation for liquids, gases and steam. The flow calculation may include compensation of pressure and/or temperature as well as more complex variables such as viscosity, discharge coefficient, thermal expansion factor, velocity of approach factor, and gas expansion factor.

Digital integration with Honeywell control systems provides local measurement accuracy to the system level without adding typical analog-to-digital (A/D) and digital-to-analog (D/A) converter errors.

SmartLine Multivariable Transmitters combine integrated sensor and microprocessor technologies as well as dynamic flow compensation to produce the most accurate and consistent flow measurement possible. The transmitters help improve product yield and increase energy efficiency, while significantly lowering the total cost of ownership.

Documentation
7 Documents FoundItems per page :
TitleUse SHIFT+ENTER to open the menu (new window).
DescriptionUse SHIFT+ENTER to open the menu (new window).
File SizeUse SHIFT+ENTER to open the menu (new window).
TypeUse SHIFT+ENTER to open the menu (new window).
Release DateUse SHIFT+ENTER to open the menu (new window).
SmartLine Transmitters for Gas Industry Solution NoteThis solution notes describes the benefits of using the SmartLine transmitters in the gas industry.728.91 KBApplication Note13 Jan 2017
SmartLine Pressure Selection GuideGuidance on how to choose a SmartLine Pressure or SmartLine Multivariable Transmitter1.58 MBModel Selection Guide9 Dec 2016
SmartLine Value for End Users Solution NoteSmartLine Transmitters Help Reduce Start-Up Delays & Maintenance Costs While Improving Plant Uptime and Profitability for End-Users.679.92 KBApplication Note9 Nov 2015
SmartLine’s Smarter Displays Provide More Field DataApplication Note on achieving more field data using SmartLine's smarter displays.65.78 KBApplication Note22 Nov 2013
Field Products Brochure for Power IndustryHoneywell offers a complete range of innovative products to meet application requirements in the power and energy markets.4.28 MBBrochure5 Nov 2013
Thermal Industry Brochure Sep 2013Solutions for Improved Thermal Process Performance.858.43 KBBrochure3 Oct 2013
Multi-Variable Trip Switch for Smart Transmitters Specification, 34-MV-03-02Multi-Variable Trip Switch for Smart Transmitters 116.82 KBTech Spec9 Jan 1999
Public Support Documentation
5 Documents FoundItems per page :
TitleUse SHIFT+ENTER to open the menu (new window).
DescriptionUse SHIFT+ENTER to open the menu (new window).
TypeUse SHIFT+ENTER to open the menu (new window).
Release DateUse SHIFT+ENTER to open the menu (new window).
Installing the Display Module, 34-ST-33-65Instruction sheet for SmartLine Transmitters: ST 700 & ST 800 Pressure Transmitters, STT 850 & STT 750 Temperature Transmitter, SLG 700 Level Transmitter and SMV 800 Multivariable TransmitterSupport Document24 Feb 2017
Installing the Communication Module, 34-ST-33-69Instruction sheet for Smartline ST 700 & ST 800 Pressure Transmitters, STT 850 & STT 750 Temperature Transmitter, SLG 700 Level Transmitter and SMV 800 Multivariable TransmitterSupport Document24 Feb 2017
SmartLine Multivariable Configuration Pocket Guide, 34-SM-00-05SMV Display menusSupport Document2 Feb 2016
STT 850, STT 750 & SMV 800 Terminal Block Module Instruction sheet, 34-TT-33-02SmartLine STT 850, STT 750 Temperature Transmitters & SMV 800 Multivariable Transmitter. Support Document9 Nov 2015
RMA803 & SMV 800 Loop Ferrite Core Instruction Sheet, 34-ST-33-75RMA803 SmartLine Remote Indicator - Instruction Support Document6 Nov 2015
 
 
 
 
Public Support Software Download
4 Documents FoundItems per page :
TitleUse SHIFT+ENTER to open the menu (new window).
DescriptionUse SHIFT+ENTER to open the menu (new window).
TypeUse SHIFT+ENTER to open the menu (new window).
Release DateUse SHIFT+ENTER to open the menu (new window).
HART Device Description (DD) files for Honeywell HART DevicesAll Honeywell HART device DDs for Experion, FDM, MCT202/MCT404, AMS HostsSoftware Download28 Jun 2017
Firmware upgrade Tool for SmartLine devicesFirmware upgrade Tool for SmartLine devices; compatibility with Windows XP, Windows 7, Windows 8, Windows 10Software Download19 Oct 2016
HART Device Description (DD) files for Honeywell HART DevicesAll Honeywell HART device DDs for Experion, FDM, MCT202/MCT404, AMS HostsSoftware Download18 Aug 2016
Honeywell Enhanced HART DTM Library HART V2.4.39.365Honeywell Enhanced HART DTM Library for Honeywell HART DeviceSoftware Download5 Dec 2015
Want to learn more about SmartLine Multivariable Transmitters?

Finding the information you need is important to us.

Did you find what you were looking for today?

  Yes      No

How likely are you to recommend HoneywellProcess.com to a colleague?

  • 0
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10

Not at all likely

Extremely likely

How can we serve you better?

Your email:

Your email address will help us get in touch with you to resolve your query/ concern.