Product Support
Find documentation, notices, downloads, and updates for your products.
See more |
| |
Request Support
Can't find the answer to your problem? Submit a request for support.
See more |
| |
Support Newsletter
Sign up for new release and product updates for your product.
See more |
|
Course Schedule
Interested in Honeywell Automation College Training? Find offerings by location, language, or program.
See more |
| |
E-Learning
Automation College offers computer-based learning, live e-Learning and web-based learning.
See more |
| |
Training Locations
Honeywell's Automation College facilities provides classes that pertain to how you will use that product in your job.
See more |
| |
Training Programs
Honeywell offers training programs that include best practices to implement, maintain, and optimize your systems.
See more |
|
|
|
Page Content The DR4500 is a 12” circular chart recorder aimed at applications in food processing, pharmaceuticals, heat treatment, environmental testing, manufactured goods and water/waste water treatment. It creates its own chart, thereby eliminating the need for an inventory of preprinted charts and providing flexibility to the user. It is RS-485 Modbus communications enabled and has an integral PID controller.
|
|
|
What is it The DR4500 circular chart recorder is a microprocessor-based recorder suitable to meet a wide range of industry requirements. It comes with a digital display and easy-to-use operator interface, and is available in many models to cater to the specific needs of different applications such as flow and HTST dairy processes. The Truline pen provides a convenient method to document a process while minimizing maintenance hassles. An integral PID controller and RS-485 Modbus communications ensure user empowerment. This accurate and easily configurable recorder is designed to work in tough industrial situations.
|
|
How it works Honeywell Truline circular chart recorders accept directly connected process signals which allow them to process data and create the chart under actual environmental conditions, eliminating the risk of temperature and humidity expansion of the paper and enhancing its accuracy. The chart recorders use single or dual pens or a “hot-stylus” type pen to produce the chart image. The simple design of these chart recorders makes them easy to operate even by inexperienced operators, and the modular construction makes them easy to maintain, modify and service. The bright, digital display and a dedicated configuration keypad bring further convenience to the user. These chart recorders come with NEMA 3 or NEMA 4 front face protection, making them suitable for tough production environments.
|
What Problems Does It Solve?
|
Problem it solves The DR4500 circular chart recorder eliminates the need to purchase individual circular charts for each application with its single circular chart requirement, thereby enabling cost savings to the user through reduced stocking of multiple circular charts.
|
|
Documentation | |
16 Documents Found | Items per page : |
DR4500 Classic Configuration Worksheet | Worksheet to document the DR4500 Classic Circular Chart Recorder configuration | 56.49 KB | Tech Spec | 15 Feb 2007 |
DR45AW Truline® Open Channel Flow Circular Chart Recorder Specification, 44-45-03-11 | DR45AW Truline® Open Channel Flow Circular Chart Recorder Specification | 309.57 KB | Tech Spec | 1 Aug 2002 |
DR45AR Truline® Circular Chart Relay Expansion Recorder Specification, 44-45-03-12 | DR45AR Truline® Circular Chart Relay Expansion Recorder Specification | 305.12 KB | Tech Spec | 1 Aug 2002 |
DR4500A Truline® Circular Chart Recorder Specification, 44-45-03-14 | DR4500A Truline Circular Chart Recorder Specification | 237.13 KB | Tech Spec | 1 Aug 2002 |
DR4500A Truline® Circular Chart Recorder Specification, Russian, 44-45-03-14-RU | DR4500A Truline Circular Chart Recorder Specification | 327.72 KB | Tech Spec | 1 Aug 2002 |
DR4500A Classic Series Circular Chart Recorder Specification, 44-45-03-15 | DR4500A Classic Series Circular Chart Recorder Specification | 236.74 KB | Tech Spec | 1 Aug 2002 |
44-45-03-15-RU | DR4500A Classic Series Circular Chart Recorder | 304.53 KB | Tech Spec | 1 Aug 2002 |
DR4500A Truline HTST, STLR, and Pasteurization Flow Circular Chart Recorders Specification, 44-45-03-16 | DR4500A Truline HTST, STLR, and Pasteurization Flow Circular Chart Recorders Specification | 292.54 KB | Tech Spec | 1 Aug 2002 |
DR4300 Product Manual - French version | DR4300 Product Manual - French version. | 23.62 MB | Tech Spec | 1 Nov 1999 |
DR45AW Addendum to 44-45-25-30 | DR45AW Addendum to 44-45-25-31. | 49.44 KB | Tech Spec | 1 Jul 1999 |
|
|
|
Public Support Documentation | |
39 Documents Found | Items per page : |
DR4500 Display PCB replacement instruction_44-45-33-40 | Circular chart recorders | 44.25 KB | Support Document | 19 Apr 2018 |
DR4500 Membrane Switch Instruction, 44-45-33-29A | DR4500/4500A Circular Chart Recorder Replacement | 18.42 KB | Support Document | 21 Feb 2018 |
DR4300, DR 4500 Latch/Lock Assembly Instruction, 44-45-33-33B | DR 4200, DR4300, DR 4500 & DR 4500A Circular Chart Recorders Kit | 24.61 KB | Support Document | 21 Feb 2018 |
DR4500 Pen Arm Assembly Instruction, 44-45-33-35 | DR4500 & DR4500A Truline Recorder Pen Arm Assembly Kit Replacement Instruction | 116.83 KB | Support Document | 21 Feb 2018 |
DR4300, DR4500 Chart Motor Instruction, 44-45-33-37B | DR4200, DR4300, and DR4500 Recorders Replacement Kit | 37.54 KB | Support Document | 21 Feb 2018 |
DR4500/4500A Alarm Output/Digital Input PCB Instruction, 44-45-33-41 | DR 4500/4500A Circular Chart Recorder Kit | 115.86 KB | Support Document | 21 Feb 2018 |
DR 4500A Auxiliary Output Printed Circuit Board Instruction, 44-45-33-52A | DR 4500A Circular Chart Recorder Kit | 84.48 KB | Support Document | 21 Feb 2018 |
DR4500, FERRITE FILTER Kit Instruction, 44-45-33-56 | DR4500 Circular Chart recorder | 119.05 KB | Support Document | 21 Feb 2018 |
DR4500, Noise Suppression Instruction, 44-45-33-57A | DR4500 Circular Chart recorder kit | 40.08 KB | Support Document | 21 Feb 2018 |
DR4500A RS485 Modbus Communications Printed Circuit Board Instruction, 44-45-33-58 | DR4500A Circular Chart Recorder Kit | 135.24 KB | Support Document | 21 Feb 2018 |
|
|
|
|
|
|
Training and Support Overview Training, maintenance and support are critical aspects to consider when choosing a technology partner. Honeywell offers world-class training through our Automation College as well as comprehensive maintenance and support services designed to leverage your physical and intellectual assets and help you sustain and increase their value and performance over time.
|
|
|
Want to learn more about DR4500 Circular Chart Recorders?
|
|
|