HERMetic UTImeter Rtex for Restricted Operation

HERMetic UTImeter Rtex for Restricted Operation

  • Add to My Bookmarks
  • SHARE 

​Honeywell’s HERMetic UTImeter Rtex is a portable electronic liquid level gauge designed for gauging of petroleum products under restricted conditions. A restricted system exists when a marine tank vessel allows some vapors from its cargo tanks into the atmosphere under normal operating conditions.

​HERMetic UTImeter Rtex offers continuous temperature reading, ullage and  oil/water interface level detection. The unit is used for custody transfer, cargo control measurement and free water detection on marine vessels. Connected to a HERMetic vapor control valve fixed on the tank, the HERMetic UTImeter Rtex permits operation under restricted conditions.

It comes with easy access for battery exchange, and can be fitted with interchangeable adaptors for connection on different vapor control valves. The tape cleaning devices, window wiper and tape protection on all units are standard parts.

HERMetic UTImeter Rtex enables three measurements in a single operation:  

  • Ullage level measurement

  • Temperature verification

  • Oil-water interface level identification. 

​The sensor of HERMetic UTImeter Rtex is calibrated once at the factory and does not require subsequent calibration. The temperature probe is an RTD element and its characteristics are stored inside the sensor. The sensor sends true temperature values to the electronic package. Therefore, changing a sensor or a tape does not require a new calibration.

The unit complies with a host of regulations, including:

  • IMO (Solas 74, MARPOL 73/78)

  • ISO (4512, 3170, 4268)

  • API (MPMS Chap 3.1A, MPMS Chap 7, MPMS Chap 8.1, MPMS Chap 17.11 )

  • IP (PMM Part III-1, PMM Part IV)

  • EC Directive 89/336/EEC (EMC)

  • EC Directive 94/9/EC (MED)

  • EC Directive 96/98/EC (ATEX 100a).

It has been approved by:

  • National authorities (USCG, MSA, GOST-R)

  • All major classification societies

  • ATEX, IECEx, Factory Mutual, NEPSI, GOST standard. 

Honeywell’s HERMetic UTImeter Rtex allows static verification of the content in a tank and continuous temperature reading of the liquid with incomparable repeatability. The fully modular unit ensures high accuracy and stability, while reducing maintenance costs for users.

Documentation
4 Documents FoundItems per page :
TitleUse SHIFT+ENTER to open the menu (new window).
DescriptionUse SHIFT+ENTER to open the menu (new window).
SizeUse SHIFT+ENTER to open the menu (new window).
TypeUse SHIFT+ENTER to open the menu (new window).
Release DateUse SHIFT+ENTER to open the menu (new window).
Service Stations for HERMetic ProductsThis is a list of Honeywell Tanksystem service stations across the globe for HERMetic products. 121.27 KBBrochure9 Feb 2015
Portable electronic level gauge UTImeter Rtex for restricted operationHERMetic UTImeter Rtex Datasheet374.67 KBBrochure11 Mar 2013
Product Catalog - Honeywell Tanksystem for Marine Applications Complete product overview of the offering from Honeywell Tanksystem dedicated to marine applications.2.14 MBBrochure30 Nov 2012
HERMetic UTImeter RtexThe HERMetic UTImeter Rtex is a portable liquid level gauge designed for level gauging of petroleum products under restricted operation.432.87 KBBrochure19 Oct 2012
Public Support Documentation
4 Documents FoundItems per page :
TitleUse SHIFT+ENTER to open the menu (new window).
DescriptionUse SHIFT+ENTER to open the menu (new window).
SizeUse SHIFT+ENTER to open the menu (new window).
TypeUse SHIFT+ENTER to open the menu (new window).
Release DateUse SHIFT+ENTER to open the menu (new window).
Hermetic UTImeter Rtex User ManualOperation and service manual for UTImeter Rtex in English.3.06 MBSupport Manual29 Nov 2012
Hermetic UTImeter Rtex with MMC Connection User ManualOperation and Service Manual in English for UTImeter Rtex with MMC connection.1.83 MBSupport Manual26 Oct 2012
Hermetic UTImeter Rtex with Tanktech Connection manual (English)Operation and service manual in English for UTImeter Rtex with Tanktech connection.2.15 MBSupport Manual26 Oct 2012
Hermetic UTImeter Rtex User manual in Russian Operation and Service manual for Hermetic UTImeter Rtex in Russian.6.41 MBSupport Manual15 Oct 2012
Maintenance and support are critical aspects to consider when choosing a technology partner. Honeywell Tanksystem provides a comprehensive and detailed operation & service manual with all its equipment that allows users to perform repairs or parts exchange without sending the unit back to factory. The common operation manual can be downloaded from the documentation tab of the respective product pages. Please contact tanksystem@honeywell.com if you can’t find the manual of your particular model. An official service station network is also available to assist you with maintenance or calibration of Tanksystem equipment. Check the Service Station list in the operation manual to find the closest service station or download the full list from the documentation tab on the product or service pages.
 
Get Microsoft SilverlightHERMetic UTImeter Rtex
 
 
 
Want to learn more about HERMetic UTImeter Rtex for Restricted Operation?

Finding the information you need is important to us.

Did you find what you were looking for today?

  Yes      No

How likely are you to recommend HoneywellProcess.com to a colleague?

  • 0
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10

Not at all likely

Extremely likely

How can we serve you better?

Your email:

Your email address will help us get in touch with you to resolve your query/ concern.